3-45

CHECKING AND CHARGING THE BATTERY

CHK

ADJ

Do not quick charge a battery.

Make sure that the battery vent is free of
obstructions.

Never remove the MF battery sealing
caps.

Do not use a high-rate battery charger.
They force a high-amperage current
into the battery quickly and can cause
battery overheating and battery plate
damage.

If it is impossible to regulate the charg-
ing current on the battery charger, be
careful not to overcharge the battery.

When charging a battery, be sure to re-
move it from the motorcycle. (If charg-
ing has to be done with the battery
mounted on the motorcycle, discon-
nect the negative lead from the battery
terminal.)

To reduce the chance of sparks, do not
plug in the battery charger until the bat-
tery charger leads are connected to the
battery.

Before removing the battery charger
lead clips from the battery terminals, be
sure to turn off the battery charger.

Make sure that the battery charger lead
clips are in full contact with the battery
terminal and that they are not shorted.
A corroded battery charger lead clip
may generate heat in the contact area
and a weak clip spring may cause
sparks.

If the battery becomes hot to the touch
at any time during the charging pro-
cess, disconnect the battery charger
and let the battery cool before recon-
necting it. Hot batteries can explode!

As shown in the following illustration,
the open-circuit voltage of a MF battery
stabilizes about 30 minutes after charg-
ing has been completed. Therefore,
wait 30 minutes after charging is com-
pleted before measuring the open-cir-
cuit voltage.