8-48
2
Tester (+) lead
Brown lead
Tester (–) lead
Black / Red lead
6. Voltage
Connect the pocket tester (DC 20 V) to the
bulb socket connector.
Turn the main switch to “ON”.
Check the voltage (12 V).
The wiring circuit from the main switch to the
bulb socket connector is faulty, repair it.
MEETS
SPECIFICATION
OUT OF SPECIFICATION
This circuit is not faulty.
1
5. Start switch
Disconnect the right handlebar switch cou-
pler from the wire harness.
Check for continuity as follows:
Blue/ White
– Black
Replace the right handlebar switch.
CONTINUITY
NO CONTINUITY
2
1
1
2
SIGNAL SYSTEM