8-35
LIGHTING SYSTEM
ELEC
Turn the main switch to “ON”.
Turn the lights switch to “ON” or “PO”.
Check the voltage (12 V) of the “Blue” lead
on the bulb socket connector.
The wiring circuit from the main switch to the
bulb socket connector is faulty, repair it.
MEETS
SPECIFICATION
OUT OF SPECIFICATION
This circuit is not faulty.
1
1. Bulb and bulb socket
Check the bulb and bulb socket for continu-
ity.
Replace the bulb and / or bulb socket.
CONTINUITY
NO CONTINUITY
Tester (+) lead
Blue / Red terminal
Tester (–) lead
Black terminal
2. Voltage
Connect the pocket tester (DC 20 V) to the
bulb socket connector.
Turn the main switch is “ON”.
Turn the lights switch to “ON” or “PO”.
Check the voltage (12 V) of the “Blue / Red”
lead on the bulb socket connector.
The wiring circuit from the main switch to the
bulb socket connector is faulty, repair it.
MEETS
SPECIFICATION
OUT OF SPECIFICATION
This circuit is not faulty.
2
EB805023
4. If the auxiliary light fails to come on: