 Chapter 10 CFM Commands

Ethernet Switch CLI Reference Guide

57

This example assigns a virtual MAC address to port 3 and displays the MAC addresses of the 
ports 2 ~ 4. The assigned virtual MAC address should be unique in both the Switch and the 
network to which it belongs. 

This example sets the Switch to carry its host name and management IP address 192.168.100.1 
in CFM packets. 

This example shows remote MEP database information. The remote MEP has been configured 
to carry its host name and a specified IP address in CFM packets.

sysname# config

sysname(config)# interface port-channel 3

sysname(config-interface)# ethernet cfm virtual-mac 00:19:cb:12:34:56

sysname(config-interface)# exit

sysname(config)# exit

sysname# show ethernet cfm virtual-mac port 2-4

Virtual MACPort MAC

---- -----------------

2    00:19:cb:00:00:02

3    00:19:cb:12:34:56

4    00:19:cb:00:00:02

sysname#

sysname# config

sysname(config)# ethernet cfm management-address-domain ip 192.168.100.1

sysnam# show ethernet cfm remote

MD Index: 1

  MD Name: customer123(string)

  MD Level: 2

  MA Index: 1

    MA Name: 123(vid)

    Primary Vlan: 123

    MEP: 11

      Remote MEP ID:    1

      MAC Address: 00:19:cb:6f:91:5a

      

Chassis Id: MGS-3712F

      Management Address: 192.168.100.1:161

sysname# 