Chapter 85 Additional Commands

Ethernet Switch CLI Reference Guide

328

This example looks at the current sensor readings from various places in the hardware.

The following table describes the labels in this screen.

sysname# show hardware-monitor C

Temperature Unit : (C)

Temperature(%c)  Current    Max    Min  Threshold  Status

---------------  -------  -----  -----  ---------  ------

           CPU      33.0   35.0   28.0       85.0  Normal

           MAC      31.0   33.0   27.0       75.0  Normal

         LOCAL      33.0   34.0   28.0       75.0  Normal

FAN Speed(RPM)  Current   Max   Min  Threshold  Status

--------------  -------  ----  ----  ---------  ------

          FAN1     7356  7769  6569       3000  Normal

          FAN2     6087  6279  6020       3000  Normal

          FAN3     6157  6301  6067       3000  Normal

Voltage(V)  Current    Max    Min  Threshold  Status

----------  -------  -----  -----  ---------  ------

   1.25VIN    1.243  1.256  1.243      +/-6%  Normal

    1.8VIN    1.869  1.880  1.869      +/-6%  Normal

    3.3VIN    3.372  3.398  3.372      +/-6%  Normal

    2.5VIN    2.593  2.593  2.593      +/-6%  Normal

Table 186   

show hardware-monitor

LABEL

DESCRIPTION

Temperature Unit

This field displays the unit of measure for temperatures in this screen.

Temperature

This field displays the location of the temperature sensors.

Current

This field displays the current temperature at this sensor.

Max

This field displays the maximum temperature measured at this sensor.

Min

This field displays the minimum temperature measured at this sensor.

Threshold

This field displays the upper temperature limit at this sensor.

Status

Normal: 

The current temperature is below the threshold.

Error

: The current temperature is above the threshold.

FAN Speed(RPM)

This field displays the fans in the Switch. Each fan has a sensor that is 
capable of detecting and reporting when the fan speed falls below the 
threshold.

Current

This field displays the current speed of the fan at this sensor.

Max

This field displays the maximum speed of the fan measured at this sensor.

Min

This field displays the minimum speed of the fan measured at this sensor. It 
displays "<41" for speeds too small to measure. (See the User’s Guide to 
find out what speeds are too small to measure in your Switch.)

Threshold

This field displays the minimum speed at which the fan should work.

Status

Normal

: This fan is running above the minimum speed.

Error

: This fan is running below the minimum speed.

Voltage(V)

This field displays the various power supplies in the Switch. Each power 
supply has a sensor that is capable of detecting and reporting when the 
voltage is outside tolerance.