Chapter 66 Smart Isolation Commands

Ethernet Switch CLI Reference Guide

264

connects to switch 

C

. Traffic from isolated ports on switch 

B

 can only be sent through non-

isolated port 

1

 or root port 

7

 to switch 

A

. This prevents isolated ports on switch 

B

 sending 

traffic through designated port 

8

 to switch 

C

. Traffic received on designated port 

8 

from 

switch 

C

 will not be forwarded to any other isolated ports on switch 

B

. 

You should enable RSTP or MRSTP before you can use smart isolation on the Switch. If the 
network topology changes, the Switch automatically updates the isolated port list with the 
latest designated port information. 

The uplink port connected to the Internet should be the root port. Otherwise, 
with smart isolation enabled, the isolated ports cannot access the Internet.

66.2  Command Summary

The following section lists the commands for this feature.

A

B

C

Isolated ports: 2~6, 8
Root port: 7
Designated port: 8

Isolated ports: 2~6
Root port: 7
Designated port: 8

Before Smart Isolation

:

After Smart Isolation:

Table 144   

smart-isolation Command Summary 

COMMAND

DESCRIPTION

M

P

no smart-isolation

Disables smart isolation on the Switch.

C

13

show smart-isolation

Enables smart isolation on the Switch.

E

3

smart-isolation

Displays the smart isolation status and information on the 
Switch.