Chapter 63 RMON

Ethernet Switch CLI Reference Guide

256

This example shows you how to configure an alarm using the following settings:

• alarm index number: 2

• variable: getting the number of errored packets received on port 1

• how often to get a data sample: every 60 seconds

• sampling method: delta

• when to send an alarm: when the value is higher than the rising threshold

• the rising threshold: 50

• which event’s action should be taken for the rising alarm: 2 (see 

Section 63.3.1 on page 

255

)

• the falling threshold: 0

• which event’s action should be taken for the falling alarm: 0 (see 

Section 63.3.1 on page 

255

)

• who will handle this alarm: operator

interval

-integer

This is the time interval (in seconds) between data samplings.

absolute

|delta

This is the method of obtaining the sample value and calculating the value to be 
compared against the thresholds.
•

absolute

 -  the sampling value of the selected variable will be compared directly 

with the thresholds. 

•

delta

 - the last sampling value of the selected variable will be subtracted from 

the current sampling value first. Then use the difference to compare with the 
thresholds.

startup-
alarm

Specify when the Switch should generate an alarm regarding to the rising and/or 
falling thresholds.
•

risingAlarm

 - the Switch generates an alarm if the sampling value (or 

calculated value) is greater than or equal to the rising threshold.

•

fallingAlarm

 - the Switch generates an alarm if the sampling value (or 

calculated value) is less than or equal to the falling threshold.

•

risingOrFallingAlarm

 - the Switch generates an alarm either when the 

sampling value (or calculated value) is greater than or equal to the rising 
threshold or when the sampling value (or calculated value) is less than or equal to 
the falling threshold.

rising-
integer

Specify an integer for the rising threshold. When a value that is greater or equal to 
this threshold, the Switch generates an alarm.

rising-

event-

index

Specify an event’s index number (between 0 and 65535). The Switch will take the 
corresponding action of the selected event for the rising alarm. Set this to 0 if you do 
not want to take any action for the alarm.

falling-
integer

Specify an integer for the falling threshold. When a value that is smaller or equal to 
this threshold, the Switch generates an alarm.

falling-

event-

index

Specify an event’s index number (between 0 and 65535). The Switch will take the 
corresponding action of the selected event for the falling alarm. Set this to 0 if you do 
not want to take any action for the alarm.

owner

Specify who should handle this alarm.