 Chapter 10 CFM Commands

Ethernet Switch CLI Reference Guide

55

10.5  Command Examples

This example creates 

MD1

 (with MD index 1 and level 1) and 

MA2

 (with MA index 2 and 

VLAN ID 2) under 

MD1

 that defines a CFM domain.

Remember to save new settings using the 

write memory

 command. 

This example deletes 

MA2

 (with MA index 2) from 

MD1 

(with MD index 1). 

This example creates 

MA3

 (with MA index 3 and VLAN ID 123) under 

MD1

, and associates 

port 1 as an MEP port with MEP ID 301 in the specified CFM domain. This also sets MHF 
(MIP half function) to 

default

 to have the Switch automatically create MIPs for this MA and 

on the ports belonging to this MA's VLAN when there are no lower configured MD levels or 
there is a MEP at the next lower configured MD level on the port. This also sets a remote MEP 
in 

MA3

.

 

sysname# config

sysname(config)# ethernet cfm md 1 format string name MD1 level 1

sysname(config)# ethernet cfm ma 2 format string name MA2 md 1 primary-

vlan 2

sysname(config-ma)# exit

sysname(config)# exit

sysname# write memory

sysname# config

sysname(config)# no ethernet cfm ma 2 md 1

sysname(config)# exit

sysname# write mem

sysname# config

sysname(config)# ethernet cfm ma 3 format string name MA3 md 1 primary-vlan 

123

sysname(config-ma)# mep 301 interface port-channel 1 direction up priority 2

sysname(config-ma)# mep 301 interface port-channel 1 direction up priority 2 

cc-enable

sysname(config-ma)# mhf-creation default

sysname(config-ma)# remote-mep 117

sysname(config-ma)# exit

sysname(config)# exit

sysname# write mem