332

This example displays the firmware versions of the dual firmware images..

This example runs an internal loopback test on ports 3-6.

This example displays route information to an Ethernet device with IP address 

192.168.1.100

.

sysname# show version flash

  Flash 1 ZyNOS version : V3.80(BBA.3)b1 | 04/17/2008

  Flash 2 ZyNOS version : V3.80(BBB.3)b0 | 04/02/2008

sysname# test interface port-channel 3-6

Testing internal loopback on port 3 :Passed!

  Ethernet Port 3 Test ok.

Testing internal loopback on port 4 :Passed!

  Ethernet Port 4 Test ok.

Testing internal loopback on port 5 :Passed!

  Ethernet Port 5 Test ok.

Testing internal loopback on port 6 :Passed!

  Ethernet Port 6 Test ok.

sysname> traceroute 192.168.1.100

traceroute to 192.168.1.100, 30 hops max, 40 byte packet

  1:192.168.1.100 (10 ms) (10 ms) (0 ms)

traceroute done:

sysname>