Инструкция для Zyxel MES3500-10 :: Страница 284 из 364
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

Chapter 72 Subnet-based VLAN Commands

Ethernet Switch CLI Reference Guide

284

72.3  Command Examples

This example configures a subnet-based VLAN (

subnet1VLAN

) with priority 

6

 and a VID of 

200

 for traffic received from IP subnet 

172.16.37.1/24

.

no subnet-based-vlan source-ip 

<

ip

> mask-bits <

mask-bits

>

Removes the specified subnet from the subnet-based VLAN 
configuration.

C

13

no subnet-based-vlan dhcp-vlan-

override

Disables the DHCP VLAN override setting for subnet-based 
VLAN(s).

C

13

Table 156   

subnet-based-vlan Command Summary  (continued)

COMMAND

DESCRIPTION

M

P

sysname# subnet-based-vlan name subnet1VLAN source-ip 172.16.37.1 mask-bits

--> 24 vlan 200 priority 6

sysname(config)# exit

sysname# show subnet-vlan

Global Active :Yes

       Name       Src IP  Mask-Bits  Vlan  Priority  Entry Active

-----------  -----------  ---------  ----  --------  ------------

subnet1VLAN  172.16.37.1         24   200         6             1