Measurement Preparations

Sprinter 150/150M/250M - 1.0.0en

EN
DE
FR
ES

NO

SV

FI

DA

IT

PT
NL

Accessories

Tripod, aluminum staff (region dependant), fibre glass staff (to 

achieve 0.7 mm accuracy with Sprinter 250M). (Optional: 

sunshade, 4 rechargeable batteries and charger)

3.

Measurement Preparations

3.1 Change Battery

Insert 4 AA dry cells according to the positive and negative signs as 

indicated on the holder. 

)

Always replace with a complete battery set!

)

Do not use old and new batteries together.

)

Do not use batteries from different manufacturers or 

batteries of different types.

3.2 Set-up Instrument

Levelling

• Set up the tripod. Extend the legs to a suitable length and ensure 

that the tripod head is approximately level. Tread the tripod 

shoes firmly into the ground to ensure stability. 

• Mount the instrument on the tripod by screwing the tripod screw 

onto the base of the instrument. 

• Use the three levelling foot screws to center the circular bubble 

in order to level the instrument.

Eyepiece Adjustment

Point the telescope to a uniform light surface such as a wall or a 

piece of paper. Turn the eyepiece until the cross hairs are sharp or 

distinct.

Target Image Focusing

Use the gunsight to aim the objective lens at the staff. Turn the hori-

zontal fine motion screw until the staff is nearly centered in the field 

of view and then turn the focusing knob to focus on the staff. Ensure 

that staff image and reticle are sharp or distinct.

Power ON

The instrument is ready to measure.

)

Technical hints: 

• First check and adjust the electronic and optical line-of-sight 

errors, then the circular level on the instrument and then the staff: 

before starting work in the field, after long storage periods, after 

long transportation. 

• Keep the optics clean. Dirt or condensation on the optics can 

limit measurements. 

• Before starting work, let the instrument adjust to the ambient 

temperature (approx. 2 minutes per °C of temperature differ-

ence). 

• Avoid measuring through window panes. 

• Staff sections have to be fully extended and properly secured. 

• Touching the upper third of the tripod, can damp vibrations at the 

instrument due to wind. 

• Use the lens hood to cover the objective when backlight disturbs. 

• Evenly illuminate the measuring area of the staff with a flashlight 

or spotlight in darkness.