13. Technical Data

Height measurements

Standard deviation per km double run (ISO 17123-2):

• Electronic measurement with Sprinter aluminum barcode staff: 

• 1.0 mm (Sprinter 250M)

• 1.5 mm (Sprinter 150/150M)

• Optical measurement with standard aluminum E-scale/Numeral staff: 2.5 mm

• Standard Deviation for single staff reading: 0.6 mm (electronic) and 1.2 mm (optical) at 30m

Distance Accuracy 

(Standard Deviation)

10 mm for D<= 10 m

Distance in m x 0.001 for D>10 m

Range

Distance measuring range for electronic measurements with standard aluminum barcode staff: 2 m to 

100 m.

Optical - Shortest focusing 

distance

50 cm

Measuring time single 

measure (Electronic)

Typically 3 seconds and less in normal daylight condition; needs longer measuring time in uniform dim 

light condition (20 lux).

Circular Bubble

Circular Bubble Sensitivity: 10'/2 mm

Compensator

Magnet damped pendulum compensator with electronic range monitoring

• Tilt Warning Range (Electronically): ± 10' 

• Compensator range (Mechanically): ± 10' 

• Setting accuracy: 0.8" max. (Standard Deviation) 

• Magnetic field sensitivity: < 10" 

(Line-of-sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss)

RS232 Port*

For RS232 cable connection to external battery and communication to PC / data collector.

Phone Jab Port*

For USB cable connection to communication to PC.