Инструкция для Leica Sprinter 150M :: Страница 14 из 380
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

11

Operation

Sprinter 150/150M/250M - 1.0.0en

EN
DE
FR
ES

NO

SV

FI

DA

IT

PT
NL

6.3

Cut & Fill Measurement* (internal Memory active)

Measure to Bench-

mark with prompt 

message

Go to menu update 

Design Elevation

Measurement to 

Benchmark 

displayed

Prompt message 

measure to target

Measurement to 

target displayed

RfID:

BM:

D.Elv:

 

           BM1

 

  100.038m

      

0.000m

Meas Reference

Change RfID, BM & 

D.Elv goto menu 

RfID:

BM:

D.Elv:

 

           BM1

 

  100.038m

   

100.500m

Meas Reference

Change RfID, BM & 

D.Elv goto menu 

: 
:

RfID :

                 

BM1

 

      1.235m

        

5.68m

Meas.Target !

PtID:

 

        

Elv.: 

SLAB 1
99.563 m
  1.710 m
  0.937 m

:

Step Key/Screen Description

1.

Press Menu key and select Cut & Fill applica-

tion in the Program sub-menu.

2.

A message "Meas. Reference" with input 

Benchmark reduced level value and Design 

Elevation is displayed. 

3.

Press measuring key to initiate measurement 

with respect to the Reference staff / Bench-

mark.

4.

Reference height and distance measurement 

is displayed; follow by a message "Meas. 

Target!" prompted.

5.

Again, press measure key to start measure-

ment to target point.

6.

The following results are displayed accord-

ingly- target reduced level (RL) / Elevation, 

height of target point and cut / fill value at 

target point with respect to the Design 

reduced level / Design Elevation.