ELECTRICAL SYSTEM 9-11
GENERATOR NO-LOAD PERFORMANCE
• Lift and support the fuel tank. (
5-3)
• Disconnect the generator coupler.
• Start the engine and keep it running at 5 000 r/min.
• Using the multi-circuit tester, measure the voltage between
three lead wires.
If the tester reads under the specified value, replace the gen-
erator with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Voltage (~)
Generator no-load performance:
65 V and more at 5 000 r/min (When engine is cold)
REGULATOR/RECTIFIER
• Lift and support the fuel tank. (
5-3)
• Remove the air cleaner box. (
5-14)
• Disconnect the regulator/rectifier couplers.
• Measure the voltage between the lead wires using the multi
circuit tester as indicated in the table below. If the voltage is
not within the specified value, replace the regulator/rectifier
with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Diode test (
)
Unit: V
1.4 V and more (tester’s battery voltage)
NOTE:
If the tester reads 1.4 V and below when the tester probes are
not connected, replace its battery.
Y
Y
Y
+
Probe of tester to:
-
P
ro
be o
f tes
ter
to:
B/R
1
B/R
2
B
1
B
2
B
3
B/W
1
B/W
2
B/R
1
0
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
B/R
2
0
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
B
1
0.4 – 0.7 0.4 – 0.7
B
2
0.4 – 0.7 0.4 – 0.7
B
3
0.4 – 0.7 0.4 – 0.7
B/W
1
0
B/W
2
0
B/R
2
B/R
1
B/W
1
B/W
2
B
1
B
2
B
3