4-30     FI SYSTEM DIAGNOSIS

DTC No.

DETECTED 

ITEM

DETECTED FAILURE CONDITION

CHECK FOR

C21

IAT sensor

The sensor voltage should be the fol-
lowing.

0.15 V 

 sensor voltage < 4.85 V

In other than the above range, C21 
(P0110) is indicated.

IAT sensor, lead wire/coupler 
connection

P0110

H

Sensor voltage is higher than specified 
value.

IAT sensor circuit open or 
ground circuit open

L

Sensor voltage is lower than specified 
value.

IAT sensor circuit shorted to 
ground

C22

AP sensor

The sensor voltage should be the fol-
lowing.

0.5 V 

 sensor voltage < 4.85 V

In other than the above range, C22 
(P1450) is indicated.

AP sensor, wiring/coupler con-
nection

P1450

H

Sensor voltage is higher than specified 
value.

AP sensor circuit shorted to 
VCC or ground circuit open

L

Sensor voltage is lower than specified 
value.

AP sensor circuit open or 
shorted to ground or VCC circuit 
open

C23

TO sensor

The sensor voltage should be the fol-
lowing for 2 sec. and more, after igni-
tion switch is turned ON.

0.2 V 

 sensor voltage < 4.8 V

In other than the above value, C23 
(P1651) is indicated.

TO sensor, lead wire/coupler 
connection

P1651

H

Sensor voltage is higher than specified 
value.

TO sensor circuit shorted to 
VCC or ground circuit open

L

Sensor voltage is lower than specified 
value.

TO sensor circuit open or 
shorted to ground or VCC circuit 
open

C24/C25
C26/C27

Ignition sig-
nal

CKP sensor (pick-up coil) signal is pro-
duced, but signal from ignition coil is 
interrupted 8 times or more continu-
ously. In this case, the code C24 
(P0351), C25 (P0352), C26 (P0353) or 
C27 (P0354) is indicated.

Ignition coil, wiring/coupler con-
nection, power supply from the 
battery

P0351/P0352
P0353/P0354

C28

Secondary 
throttle valve 
actuator

When no actuator control signal is 
supplied from the ECM, communica-
tion signal does not reach ECM or 
operation voltage does not reach 
STVA motor, C28 (P1655) is indicated. 
STVA can not operate.

STVA motor, STVA lead 