4-32     FI SYSTEM DIAGNOSIS

DTC No.

DETECTED 

ITEM

DETECTED FAILURE CONDITION

CHECK FOR

C44

HO2 sensor 
(For E-02, 
19)

HO2 sensor output voltage is not input 
to ECM during engine operation and 
running condition.
(Sensor voltage < 0.55 V)
In other than the above value, C44 
(P0130) is indicated.

HO2 sensor circuit open or 
shorted to ground

P0130

C44

The Heater can not operate so that 
heater operation voltage is not supply 
to the oxygen heater circuit, C44 
(P0135) is indicated.

HO2 sensor lead wire/coupler 
connection
Battery voltage supply to the 
HO2 sensor

P0135

C46

Exhaust con-
trol valve 
actuator

EXCVA position sensor produces fol-
lowing voltage. 

0.1 V 

 sensor voltage < 4.9 V

In other than the above range, C46 
(P1675) is indicated.
When no actuator control signal is 
supplied from the ECM, communica-
tion signal does not reach ECM or 
operation voltage does not reach 
EXCVA motor, C46 (P1658) is indi-
cated. EXCVA can not operate.

EXCVA, EXCVA lead wire/cou-
pler

P1657

H

EXCVA position sensor voltage is 
higher than specified value.

EXCVA position sensor circuit 
shorted to VCC or ground circuit 
open

L

EXCVA position sensor voltage is 
lower than specified value.

EXCVA position sensor circuit 
open or shorted to ground or 
VCC circuit open

P1658

When no actuator control signal is 
supplied from the ECM, communica-
tion signal does not reach ECM or 
operation voltage does not reach 
EXCVA motor, C46 (P1658) is indi-
cated. EXCVA motor can not operate.

EXCVA, EXCVA motor lead 
wire/coupler

C49

PAIR control 
solenoid 
valve

PAIR control solenoid valve voltage is 
not input to ECM.

PAIR control solenoid valve, lead 
wire/coupler

P1656

C60

Cooling fan 
relay

Cooling fan relay signal is not input to 
ECM.

Cooling fan relay, lead wire/cou-
pler connection

P0480