4-68 FI SYSTEM DIAGNOSIS
Step 2
1) Turn the ignition switch OFF.
2) Disconnect the STVA lead wire coupler.
3) Check the continuity between each terminal and ground.
STVA continuity:
∞
Ω
(Infinity)
(Terminal – Ground)
4) If OK, then measure the STVA resistance (between terminal
A
and terminal
B
) and (between terminal
C
and terminal
D
).
STVA resistance: Approx. 7.0
Ω
(Terminal
A
– Terminal
B
)
(Terminal
C
– Terminal
D
)
09900-25008: Multi-circuit tester set
Tester knob indication: Resistance (
Ω
)
Is the resistance OK?
5) After repairing the trouble, clear the DTC using SDS tool.
(
4-27)
2
2
YES
• W/B, P/W, G and B/Lg wire open or shorted to
ground, or poor
1
,
2
,
H
and
I
connection
• If wire and connection are OK, intermittent trou-
ble or faulty ECM.
• Recheck each terminal and wire harness for
open circuit and poor connection.
• Replace the ECM with a known good one, and
inspect it again.
NO
• Loose or poor contacts on the ECM coupler.
• Replace the STVA with a new one.
When using the multi-circuit tester, do not storongly
touch the terminal of the ECM coupler with a needle
pointed tester probe to prevent the terminal damage
or terminal bend.
2
(Black)
(Gray)
ECM couplers (Harness side)