4-36 FI SYSTEM DIAGNOSIS
5) If OK, then check the continuity between each terminal and
ground.
CKP sensor continuity:
∞
Ω
(Infinity)
(B – Ground)
(G – Ground)
09900-25008: Multi-circuit tester set
Tester knob indication: Resistance (
Ω
)
Are the resistance and continuity OK?
6) After repairing the trouble, clear the DTC using SDS tool.
(
4-27)
Step 2
1) Crank the engine a few seconds with the starter motor, and
measure the CKP sensor peak voltage at the coupler.
2) Repeat the above test procedure a few times and measure
the highest peak voltage.
CKP sensor peak voltage: 0.28 V and more
(
+
B –
-
G)
1
Peak volt adaptor
09900-25008: Multi-circuit tester set
Tester knob indication: Voltage (
)
YES
Go to step 2.
NO
Replace the CKP sensor with a new one.
1
2
V