6-6 EXHAUST SYSTEM
• Tighten the EXCVA mounting bolts to the specified torque.
EXCVA mounting bolt: 6.0 N·m (0.6 kgf-m, 4.5 lb-ft)
• Turn in the two cable adjusters fully.
• Connect the No.1 cable
1
(01H0CL) and No.2 cable
2
(01H0OP) to the EXCVA pulley.
No.1 cable: 01H0CL
No.2 cable: 01H0OP
• After connecting the No.1 cable
1
, loosen the lock-nut
3
and
turn the adjuster
4
in or out until the thread length
C
becomes the measured value before disconnecting the No.1
cable
1
.
• Tighten the lock-nut
3
.
• After connecting the No.2 cable
2
, loosen the lock-nut
5
and
turn the adjuster
6
in or out until the thread length
D
becomes the measured value before disconnecting the No.2
cable.
• Tighten the lock-nut
5
.
• Connect the EXCVA lead wire couplers
7
,
8
.
EXCVA INSPECTION
4-91
The cable slots of EXCVA pulley must be located
adjustment position. (
6-4)
If the EXCVA adjustment is necessary,refer to page