Инструкция для D-Link DES-3200-28, DES-3200-28/C1, DES-3200-26 :: Страница 497 из 652
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн

Инструкция для D-Link DES-3200-28, DES-3200-28/C1, DES-3200-26

Инструкция в формате - PDF
Количество страниц - 652 страницы
Размер - 1.6 МБ
Доступно - Бесплатное скачивание
Доступно - Онлайн чтение
background image

xStack

® 

DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide 

493 

 

DES-3200-28/ME:admin#show qinq ports 1-2 

Command: show qinq ports 1-2 

 

 

Port ID:    1 

--------------------------------------------------------- 

  Role:                     NNI 

  Miss Drop:                Disabled 

  Outer Tpid:               0x8100 

  Add Inner Tag:            Disabled 

 

Port ID:    2 

--------------------------------------------------------- 

  Role:                     NNI 

  Miss Drop:                Disabled 

  Outer Tpid:               0x8100 

  Add Inner Tag:            Disabled 

 

DES-3200-28/ME:admin# 

 

56-8

 

create vlan_translation ports 

Description 

This command is used to create a VLAN translation rule. This setting will not be effective when the 
QinQ mode is disabled. 

This configuration is only effective for a UNI port. At UNI port, the ingress C-VLAN tagged packets 
will be translated to S-VLAN tagged packets by adding or replacing according the configured rule. 
The S-VLAN Tag of egress packets at this port will be recovered to C-VLAN Tag or stripped. 

 

Format 

create vlan_translation ports [<portlist> | all] [add cvid <vidlist> | replace cvid <vlanid 1-
4094>] svid <vlanid 1-4094> {priority <priority 0-7>} 

 

Parameters 

ports

 - Specify a list of ports to be configured. 

<portlist>

 - Enter the list of ports to be configured here. 

all

 - Specify that all the ports will be used for the configuration. 

add

 - Specify to add an S-Tag to the packet. 

cvid

 - Specify the customer VLAN ID used. 

<vidlist>

 - Enter the customer VLAN ID used here. 

replace

 - Specify to replace the C-Tag with the S-Tag. 

cvid

 - Specify the customer VLAN ID used. 

<vlanid 1-4094>

 - Enter the customer VLAN ID used here. 

svid

 - Specify the service provider VLAN ID used. 

<vlanid 1-4094>

 - Enter the service provider VLAN ID used here. 

priority

 - (Optional) Specify to assign an 802.1p priority to the S-Tag. If the priority is not 

specified, the priority of the ports will be set to S-TAG by default. 

<priority 0-7>

 - Enter the 802.1p S-Tag priority value here. This value must be between 0 and 

7. 

 