background image

xStack

® 

DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide 

98 

 

DES-3200-28/ME:admin#show flow_meter    

Command: show flow_meter 

 

Flow Meter Information 

------------------------------------------------------------------------------ 

Profile ID:1     Aceess ID:1     Mode : trTCM / ColorBlind 

CIR(Kbps):1000     CBS(Kbyte):2000     PIR(Kbps):2000     PBS(Kbyte):2000   

Action: 

      Conform : Permit                        Counter: Enabled 

       Exceed : Permit     Replace DSCP: 60   Counter: Enabled 

      Violate : Drop                          Counter: Disabled 

------------------------------------------------------------------------------ 

Total Entries: 1 

 

DES-3200-28/ME:admin# 

 

6-7

 

config time_range 

Description 

This command is used to define a specific range of time to activate a function on the Switch by 
specifying which time range in a day and which days in a week are covered in the time range. Note 
that the specified time range is based on the SNTP time or the configured time. If this time is not 
available, the time range will not be met. 

 

Format 

config time_range <range_name 32> [hours start_time <time hh:mm:ss> end_time <time 
hh:mm:ss> weekdays <daylist> | delete] 
 

Parameters 

time_range

 - Specify the name of the time range settings. 

<range_name 32>

 - Enter the time range name used here. This name can be up to 32 

characters long. 

hours

 - Specify the time of a day. 

start_time

 - Specify the starting time of a day.  

<time hh:mm:ss>

 - Enter the starting time here. (24-hr time). For example, 19:00 means 

7PM. 19 is also acceptable. The time specified in the start_time parameter must be 
smaller than the time specified in the end_time parameter. 

end_time

 - Specify the ending time of a day. (24-hr time) 

<time hh:mm:ss>

 - Enter the ending time here. (24-hr time). For example, 19:00 means 

7PM. 19 is also acceptable. The time specified in the start_time parameter must be 
smaller than the time specified in the end_time parameter. 

weekdays

 - Specify the list of days contained in the time range. Use a dash to define a period of 

days. Use a comma to separate specific days.  

<daylist>

 - Enter the weekdays that will be included in this configuration here. For example, 

mon-fri (Monday to Friday). sun, mon, fri (Sunday, Monday and Friday) 

delete

 - Deletes a time range profile. When a time_range profile has been associated with ACL 

entries, deleting the time_range profile will fail. 

 

Restrictions 

Only Administrator, Operator and Power-User level users can issue this command. 