xStack

® 

DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide 

133 

 

Chapter 12

 

Cable Diagnostics 

Command List 

 

cable_diag ports 

[<portlist> | all] 

 

12-1

 

cable_diag ports 

Description 

This command is used to configure cable diagnostics on ports. For FE port, two pairs of cable will 
be diagnosed. For GE port, four pairs of cable will be diagnosed.  

The following test result can be displayed. 

 

Open

 - The cable in the error pair does not have a connection at the specified position. 

 

Short

 - The cable in the error pair has a short problem at the specified position. 

 

Crosstalk

 - The cable in the error pair has a crosstalk problem at the specified position. 

 

Shutdown

 - The remote partner is powered off. 

 

Unknown

 - The diagnosis does not obtain the cable status. Please try again. 

 

OK

 - The pair or cable has no error. 

 

No cable

 - The port does not have any cable connected to the remote partner. 

 

When a port is in link-up status, the test will obtain the distance of the cable. Since the status is 
link-up, the cable will not have the short or open problem. But the test may still detect the crosstalk 
problem. 

When a port is in link-down status, the link-down may be caused by many factors.  

 

1.  When the port has a normal cable connection, but the remote partner is powered off, the 

cable diagnosis can still diagnose the health of the cable as if the remote partner is 
powered on. 

2.  When the port does not have any cable connection, the result of the test will indicate no 

cable. 

3.  The test will detect the type of error and the position where the error occurs. 

 

When the link partner is Fast Ethernet ports: 

 Where 

the 

link partner is powered on with no errors

 and the 

link is up

, this command 

cannot detect the cable length 

 Where 

the 

link partner is powered on with errors

, this command can detect whether the 

error is open, short, or crosstalk. In this case this command can also detect the distance of 
the error 

  Where the l

ink partner is powered down with no errors

 and the

 link is down

, this 

command cannot detect the cable length 