Инструкция для D-Link DES-3200-28, DES-3200-28/C1, DES-3200-26 :: Страница 281 из 652
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн

Инструкция для D-Link DES-3200-28, DES-3200-28/C1, DES-3200-26

Инструкция в формате - PDF
Количество страниц - 652 страницы
Размер - 1.6 МБ
Доступно - Бесплатное скачивание
Доступно - Онлайн чтение
background image

xStack

® 

DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide 

277 

 

state

 - (Optional) Specify to enable or disable the data driven learning of an IGMP snooping 

group.  

enable

 - Enter enable to enable the data driven learning option. By default, the state is 

enabled.  

disable

 - Enter disable to disable the data driven learning option.   

aged_out

 - (Optional) Enable or disable the aging out of the entry.  

enable

 - Enter enable to enable the aging out of the entry. 

disable

 - Enter disable to disable the aging out of the entry. By default, the state is disabled 

state. 

expiry_time

 - (Optional) Specify the data driven group lifetime in seconds. This parameter is 

valid only when aged_out is enabled. 

<sec 1-65535>

 - Enter the expiry time here. This value must be between 1 and 65535 

seconds. 

 

Restrictions 

Only Administrator, Operator and Power-User level users can issue this command. 

 

Example 

To enable the data driven learning of an IGMP snooping group on the default VLAN: 

DES-3200-28/ME:admin#config igmp_snooping data_driven_learning vlan_name 
default state enable 

Command: config igmp_snooping data_driven_learning vlan_name default state 
enable 

 

Success. 

 

DES-3200-28/ME:admin# 

 

30-14

 

config igmp_snooping data_driven_learning 
max_learned_entry 

Description 

This command is used to configure the maximum number of groups that can be learned by data 
driven. 

When the table is full, the system will stop the learning of the new data-driven groups. Traffic for 
the new groups will be dropped. 

 

Format 

config igmp_snooping data_driven_learning max_learned_entry <value 1-1024> 

 

Parameters 

max_learned_entry

 - Specify the maximum number of groups that can be learned by data 

driven. The default setting is 128. 

<value 1-1024>

 - Enter the maximum learning entry value here. This value must be between 

1 and 1024. 

 