Количество страниц - 652 страницы
Размер - 1.6 МБ
Доступно - Бесплатное скачивание
Доступно - Онлайн чтение
background image

xStack

® 

DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide 

291 

 

<vlanid_list>

 - Enter the VLAN ID list here. 

all

 - Specify all VLANs for which MLD snooping querier is to be configured. 

query_interval

 -  Specify the amount of time in seconds between general query transmissions. 

The default setting is 125 seconds. 

<sec 1-65535>

 - Enter the query interval value here. This value must be between 1 and 

65535 seconds. 

max_reponse_time

 -  Specify the maximum time in seconds to wait for reports from listeners. 

The default setting is 10 seconds. 

<sec 1-25>

 - Enter the maximum response time value here. This value must be between 1 

and 25 seconds. 

robustness_variable

 -  Provides fine-tuning to allow for expected packet loss on a subnet. The 

value of the robustness variable is used in calculating the following MLD message intervals: 

<value 1-7>

 - Enter the robustness variable value here. This value must be between 1 and 7. 

  Group listener interval—Amount of time that must pass before a multicast router decides 

there are no more listeners of a group on a network. This interval is calculated as follows: 
(robustness variable * query interval) + (1 * query response interval). 

  Other querier present interval—Amount of time that must pass before a multicast router 

decides that there is no longer another multicast router that is the querier. This interval is 
calculated as follows: (robustness variable * query interval) + (0.5 * query response 
interval). 

  Last listener query count—Number of group-specific queries sent before the router 

assumes there are no local listeners of a group. The default number is the value of the 
robustness variable. 

  By default, the robustness variable is set to 2. You might want to increase this value if 

you expect a subnet to be loosely. 

last_listener_query_interval

 - (Optional) Specify the maximum amount of time between group-

specific query messages, including those sent in response to done-group messages. You 
might lower this interval to reduce the amount of time it takes a router to detect the loss of the 
last listener of a group. The default setting is 1 second. 

<sec 1-25>

 - Enter the last listener query interval value here. This value must be between 1 

and 25 seconds. 

state

 - (Optional) This allows the Switch to be specified as an MLD Querier (sends MLD query 

packets) or a Non-Querier (does not send MLD query packets). Set to enable or disable. 

enable

 - Enable the MLD querier state. 

disable

 - Disable the MLD querier state. 

version

 - (Optional) Specify the version of MLD packet that will be sent by the Switch. 

<value 1-2>

 - Enter the version number value here. This value must be between 1 and 2. 

 

Restrictions 

Only Administrator, Operator and Power-User level users can issue this command. 

 

Example 

To configure the MLD snooping querier: 

DES-3200-28/ME:admin#config mld_snooping querier vlan_name default 
query_interval 125 state enable 

Command: config mld_snooping querier vlan_name default query_interval 125 state 
enable 

 

Success. 

 

DES-3200-28/ME:admin# 

 