Prestige 791R G.SHDSL Router 

System Maintenance 

 

14-7 

Table 14-3 System Maintenance Menu — Syslog Parameters 

PARAMETER DESCRIPTION 

UNIX Syslog: 

 

Active  Use [SPACE BAR] and then [ENTER] to turn syslog on or off. 

Syslog IP Address  Type the IP address of your syslog server. 

Log Facility  Use [SPACE BAR] and then [ENTER] to select one of seven different local options. 

The log facility lets you log the message in different server files. Refer to your UNIX 
manual. 

Types:  

CDR  Call Detail Record (CDR) logs all data phone line activity if set to 

Yes

. 

Packet Triggered  The first 48 bytes or octets and protocol type of the triggering packet is sent to the 

UNIX syslog server when this field is set to 

Yes

. 

Filter Log  No filters are logged when this field is set to 

No

. Filters with the individual filter Log 

Filter field set to 

Yes

 are logged when this field is set to 

Yes

. 

PPP Log  PPP events are logged when this field is set to 

Yes

. 

The following are examples of the four types of syslog messages sent by the Prestige: 

1 - CDR 

SdcmdSyslogSend ( SYSLOG_CDR, SYSLOG_INFO, String); 
String = board xx line xx channel xx, call xx, str 
board = the hardware board ID 
line = the WAN ID in a board 
Channel = channel ID within the WAN 
call = the call reference number which starts from 1 and increments by 1 for each new call 
str = C01 Outgoing Call dev xx ch xx (dev:device No. ch:channel No.) 
 

C01 Incoming Call xxxxBps xxxxx (L2TP, xxxxx = Remote Call ID) 

 

C01 Incoming Call xxxx (= connected speed) xxxxx (= Remote Call ID) 

 

L02 Tunnel Connected (L2TP) 

 

C02 OutCall Connected xxxx (= connected speed) xxxxx (= Remote Call ID) 

 

C02 CLID call refused 

 

L02 Call Terminated 

 

C02 Call Terminated 

Jul 19 11:19:27 192.168.102.2 ZYXEL: board 0 line 0 channel 0, call 1, C01 Outgoing Call dev=2 ch=0 

40002 

Jul 19 11:19:32 192.168.102.2 ZYXEL: board 0 line 0 channel 0, call 1, C02 OutCall Connected 64000 

40002 

Jul 19 11:20:06 192.168.102.2 ZYXEL: board 0 line 0 channel 0, call 1, C02 Call Terminated 

2 - Packet Triggered 

SdcmdSyslogSend (SYSLOG_PKTTRI, SYSLOG_NOTICE, String); 
 

String = Packet trigger: Protocol=xx Data=xxxxxxxxxx…..x 

 

Protocol: (1:IP 2:IPX 3:IPXHC 4:BPDU 5:ATALK 6:IPNG) 

 

Data: We will send forty-eight Hex characters to the server 

Jul 19 11:28:39 192.168.102.2 ZYXEL: Packet Trigger: Protocol=1, 

Data=4500003c100100001f010004c0a86614ca849a7b08004a5c020001006162636465666768696a6b6c6d6e6f70717273

74 