71.03982.03 - EN

INSTALLATION INSTRUCTIONS

20. VISUALISATION OF PARAMETERS ON THE DISPLAY (“INFO” FUNCTION)

Press “

i

” for at least 5 seconds to visualise certain boiler information on the display on the front panel of the boiler.

•

 

Press buttons   (

+/-

) to display the following information:

A00: 

current DHW temperature (°C);

A01: 

current external temperature (°C) (with external sensor connected);

A02: 

modulation current value (100% = 310 mA METHANE - 100% = 310 mA LPG);

A03: 

power range (%) (MAX R);

A04: 

heating setpoint temperature (°C) - - If the external sensor is connected, the value of the “

kt

” curve is displayed 

(section 26);

A05: 

current heating delivery temperature (°C);

A06: 

DHW temperature setpoint (°C);

A07: 

— — ;

A08: 

value (l/minx10) of the DHW flow rate;

A09: 

last error that occurred in the boiler.

•

 

This function remains active for 3 minutes. It is possible to interrupt the “INFO” function in advance by pressing button  
(

i

) for at least 5 seconds, or turning off the power to the boiler.

N.B:

 when the “INFO” function is enabled, the message “A00”, alternating with the boiler delivery temperature, 

is shown on the display (figure 12):

0605_2204 / CG_1808