Руководство пользователя для De Dietrich MS 24 MI FF :: Страница 100 из 332
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

100

71.03982.03 - EN

INSTALLATION INSTRUCTIONS

35. TECHNICAL SPECIFICATIONS

Model MS 

 

 

24 MI FF 

24 FF 

24 MI 

24 

Category

 

  

II

2H3P

 

II

2H3P

 

II

2H3P

 II

2H3P

Rated heat input

 

 kW 

25,8  25,8  26,3  26,3 

Reduced heat input

 

 kW 

10,6  10,6  10,6  10,6 

Rated heat output

 

 kW 

24  24  24  24 

 

  kcal/h 

20.600 20.600 20.600  20.600 

Reduced heat output

 

 kW 

9,3  9,3  9,3  9,3 

 

 kcal/h 

8.000  8.000  8.000  8.000 

Useful efficiency according to directive 92/42/EEC 

 

— 

★★★ 

★★★ 

★★ 

★★ 

Max. water pressure in CH system

 

 bar 

3 

3 

3 

3 

Expansion vessel capacity 

 

 l 

6  6  6  6 

Expansion vessel pressure

 

 bar 

1 

1 

1 

1 

DHW max. water pressure

 

 bar 

8 

— 

8 

— 

DHW min. dynamic water pressure

  

bar 

0,15 — 0,15  — 

Minimum DHW flow

 

 l/min 

2,0 

—  2,0 

— 

DHW output at ∆T=25 °C

 

 l/min 

13,7  —  13,7  — 

DHW output at ∆T=35 °C

 

 l/min 

9,8 

—  9,8 

— 

Specific output (*)

 

 l/min 

12 

— 

12 

— 

Temperature range in heating system

 

  °C 

30/85 30/85 30/85  30/85 

Temperature range in DHW system

 

  °C 

35/60 35/60*** 35/60  35/60***

Type

 

 

— 

   C12-C32-C42-C52-C82-B22

 

B

11BS 

B

11BS 

Coaxial flue duct diameter

 

 mm 

60  60 

- 

- 

Coaxial air duct diameter

 

 mm 

100  100  - 

- 

2-pipe flue duct diameter

 

 mm 

80  80 

- 

- 

2-pipe air duct diameter

 

 mm 

80  80 

- 

- 

Flue duct diameter

 

 mm 

- 

-  125  125 

Max. flue mass flow rate

 

  kg/s 

0,014 0,014 0,020  0,020 

Min. flue mass flow rate

 

  kg/s 

0,014 0,014 0,018  0,018 

Max. exhaust temperature

 

 °C 

146  146  110  110 

Min. exhaust temperature

 

 °C 

116  116  85  85 

NOx Class

 

 — 

3 

3 

3 

3 

Type of gas

 

 — 

G20 G20 G20  G20 

 

 — 

G31 G31 G31  G31 

Natural gas supply pressure

 

 mbar 

20 

20 

20 

20 

Propane gas supply pressure

 

 mbar 

37 

37 

37 

37 

Power supply voltage

 

 V 

230 230 230  230 

Power supply frequency

 

 Hz 

50  50  50  50 

Rated power supply

 

 W 

130  130  80  80 

Net weight

 

 kg 

33  32  29  28 

Dimensions 

Height  

mm 

730 

730 

730 

730

 

Width  

mm 

400 

400 

400 

400 

 

Depth  

mm 

299 

299 

299 

299 

Protection against humidity and water  

 

(**) 

IP X5D 

IP X5D 

IP X5D 

IP X5D 

(*) according to EN 625 

 

 

 

 

 

 

(**) according to EN 60529
(***) with external storage boiler

As DE DIETRICH constantly strives to improve its products, it reserves the right to modify the information contained in this document at 

any time and without prior notice. This document is issued purely for the sake of information and should not be considered as a contract 