Startup

467 772_a

17

Automatic mode

1. In automatic mode, set the adjustable foot to

position "U" (bottom) to achieve the greatest

possible feed rate.

2. Insert the mains plug into the plug socket.

Models with float switch

3. Switch the operation selection switch on the

mains switch to "AUTO" 

(Fig. G)

.

Models with level switch

4. Slide the level switch upwards to the desired

switch-on height 

(Fig. I)

.

➯

The pump switches on automatically at a

specific water level (switch-on height) by

the float switch and when the water level

falls to the switch-off height it switches off

again, see technical data Page 5

Manual operation mode

In manual mode, the water can be pumped away

to a very low level of residual water.
Minimum water level for commissioning: 

see tech-

nical data

.

Pumping out to residual water level

CAUTION!

Monitor  the  pump  continuously  when

pumping out to the residual water level

and  avoid  the  pump  running  dry.  Shut

the  pump  down  when  the  residual  wa-

ter level has been reached by switching

the  operation  mode  selector  switch  to

"AUTO". The pumps switch on again au-

tomatically when the switch-on height is

reached.

Set the adjustable foot to the "O" (top) position for

pumping out to the residual water level:
1. Remove the mains plug from the plug socket.

Models with float switch

2. Switch the operation selection switch on the

mains  switch  to  "MAN" 

(Fig.  G)

.  The  pump

switches on and starts to feed.

Models with level switch

3. Slide the level switch upwards to the "MAN"

position 

(Fig. I)

.

ADVICE

If the water drops below the residual wa-

ter level, the pump will draw air in. In this

case,  the  pump  must  be  vented  when

the water level rises and before using it

again.

MAINTENANCE AND CARE

Cleaning the pump

ADVICE

After  conveying  chlorine-containing

swimming pool water or fluids that leave

a residue, the pump must be flushed out

with clear water.

1. Clean the suction slots on the suction foot if

necessary with clear water.

Removing/fitting the level switch

see Fig. H

1. Unscrew the fixing screw

(2)

 and then first tip

the housing float switch

(1)

 upwards and then

tilt to the front.

2. Clean the float body 

(4)

 and guides 

(3)

.

3. Place the float body back in the guide.
4. Replace  the  housing  float  body  and  push

downwards.

5. Screw the fixing screw in.

Removing/fitting the adjustable foot
TWIN pumps

see Fig. F

1. Unscrew the engaging screws 

(7) 

and pull the

adjustable foot 

(6)

 out of the pump housing

(8)

.

2. Clean the adjustable foot and the pump hou-

sing.

3. Insert the adjustable foot in the pump housing,

align and screw the engaging screws back in

place.

STORAGE

ADVICE

In the event of a risk of frost, the system

must be drained completely.

DISPOSAL

Do not dispose of old

equipment,batteries or accumulators

as householdwaste!

Product, packaging, and accessories

were made with recyclable materials, and

should be disposed of accordingly.