en

Assembly

16

SUB 10000-13000 DS / TWIN 11000-14000

ASSEMBLY

Mounting the pressure line
TWIN pumps

see Fig. A

1. Screw the connection elbow 

(7)

 into the pump

outlet.

2. Screw  the  combination  nipple 

(4)

  onto  the

connection elbow.

3. Fix a hose to the combination nipple.

SUB pumps

see Fig. C

1. Screw  the  combination  nipple 

(4)

  onto  the

connection elbow.

2. Fix a hose to the combination nipple.

ADVICE

The combination nipple can be trimmed

to suit the selected hose connection. Use

the largest possible hose diameter.

Setting the adjustable foot

see Fig. E

TWIN pumps

1. Turn the adjustable foot 

(6)

 to the right.

➯

The adjustable foot disengages.

2. Set the adjustable foot to position "O" or "U".
3. Turn the adjustable foot (6) to the left.

➯

The  adjustable  foot  locks  back  in  posi-

tion.

SUB pumps

1. Turn the adjustable foot 90° to the left to move

the adjustable foot to the top position.

2. Turn  the  adjustable  foot  90°  to  the  right  to

move the adjustable foot to the bottom posi-

tion.

ADVICE

The combination nipple can be trimmed

to suit the selected hose connection. Use

the largest possible hose diameter.

STARTUP

Safety

CAUTION!

Exclude, by suitable means, that, in the

event of a fault in the immersion pump,

consequential damage is caused by floo-

ding.

Make sure that the immersion pump is stan-

ding securely or operate the immersion pump

suspended from a rope.
Make sure there is adequate clearance under

the pump.
Never  allow  the  immersion  pump  to  run

against a closed off pressure line.
When using in shafts, make sure the size is

adequate.
Always  cover  the  shaft  with  a  secure  foot-

plate.

Switching the pump on

see Fig. A - C

CAUTION!

The immersion pump must not draw in

any solid bodies. Sand and other abra-

sive materials in the conveying medium

will destroy the immersion pump.

1. Unwind the connection cable 

(1)

 completely.

2. Make sure that the electrical plug connection

is mounted in the area safe from flooding.

Models with float switch

3. Change the terminal position and adjust the

switching points of the float switch

(10)

 indivi-

dually.

4. Attach  the  cable  on  the  float  switch  to  the

pump housing

(4)

securely.

➯

Recommended cable length on the float

switch approx. 100 mm

Models with level switch

5. Slide the level switch 

(8)

 to the relevant height

and thus set the switching points.

ADVICE

Use  a  suitable  plate  to  ensure  se-

cure  mounting  of  the  immersion

pump  on  muddy,  sandy  or  stony

ground.

6. Immerse the immersion pump in the convey-

ing medium slowly. Hold the immersion pump

at a slight angle to allow any air to escape.

7. Insert the mains plug into the plug socket.

➯

The immersion pump switches on auto-

matically  using  the  float  switch  when  a

specific  water  level  has  been  reached,

and switches off again if the water drops

below the switch-off height.

Switching the pump off

1 Remove the mains plug from the plug socket.