en

Startup

18

HWA 5000/6000 FMS Premium

Filling the house water system

CAUTION!

Before commissioning, the house water

system must always be filled up to the

overflow with water, so that it can draw

water immediately. If the pump runs dry

it will be destroyed.

ADVICE

Fill  the  suction  hose  with  water  before

screwing in place to reduce the suction

time.

1. Open the filling screw 

(Fig. A -3)

 with the filter

key 

(Fig. C -19/A)

.

2. Fill  with  water  via  the  filling  screw  until  the

pump housing 

(Fig. A -2)

 is full.

3. Screw the filling screw in.

Switching the pump on

1. If necessary, in the pressure line 

(Fig. B -11)

open one of the existing closing off devices

(valve, spray nozzle, water cock).

2. Insert the mains plug on the connection cable

into the plug socket.

➯

The pumps starts to feed.

3. When no more air comes out with the water,

close  the  closing  off  device  in  the  pressure

line.

➯

The pump switches off automatically af-

ter the switch-off pressure has been re-

ached.

➯

The house water system is ready for ope-

ration.

➯

When  switching  on  via  the  pressure

switch  the  display  shows  NORMAL  X

and PRESSURE together with the actual

pressure.

Initial commissioning

Only on initial commissioning, the display shows

NORMAL X and PRESSURE.

ADVICE

If no water is drawn up via the suction

line 

(Fig. B -17)

 in approx. 90 seconds,

the  dry  running  protection  switches  off

the pump, and the display shows ALARM

and SUCTION SIDE. Check the suction

line, the clear sight cover 

(Fig. A -1)

 and

all  the  screwed  fittings  for  leaks,  press

the RESET button and carry out the in-

itial commissioning again.

Switching the pump off

1. Remove the mains plug from the plug socket.
2. Close all the closing off devices (valves, spray

nozzles, water cock) in the pressure line.

ADVICE

The  pump  switches  off  automatically

when  the  set  switch-off  pressure  is

achieved.

CAUTION!
Danger of injury from hot water

In extended use against the closed pres-

sure  side  (>10  min.),  the  water  in  the

pump can be severely heated up and can

be  emitted  in  an  uncontrolled  manner!

Isolate the unit from the mains and allow

the pump and water to cool down. Start

the unit again only after all the faults have

been rectified!

The risk of injury from hot water can arise if:

the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.

Procedure

1. Isolate the unit from the mains and allow the

pump and water to cool down.

2. Check the unit, the installation and water le-

vel.

3. Start  the  unit  again  only  after  all  the  faults

have been rectified!

MAINTENANCE AND CARE

Check the air pressure in the storage vessel

CAUTION!

Check  the  air  pressure  in  the  storage

vessel at regular intervals. It must not ex-

ceed 1.5 bar (see Section "Commissio-

ning:  Checking  the  Air  Pressure  in  the

Storage Vessel").

CAUTION!

If  the  display  shows  the  information

ALARM and REFILL 1.5 BAR, you need

to top up the air in the diaphragm stor-

age vessel. When the correct pressure is

achieved, th display shows ALARM and

AIR PRESSURE OK.