Group

Programming Guide

155

Parameter

[Overflow Setting] Destination – Day / Night

Default

Blank

Value Range

3-4 digits consisting of 0-9

Description/Function

Specifies the destination extension where the call is transferred to
when all extensions in the Incoming Group are unavailable or
logged-out in Day / Night mode respectively.
(Assignable only when "Terminate," "Operator" or "UCD" is
specified in "Group Type" programming.)

Note

•

A single extension can be assigned to up to eight different
Incoming Groups at a time.

Reference

None

Parameter

[Overflow Setting] Timer

Default

None

Value Range

None, 5-180 s in 5 s increments

Description/Function

Specifies the length of time in seconds the system is to wait before
transferring the call in the waiting queue to the Overflow
Destination.
(Assignable only when "Operator" is specified in "Group Type"
programming.)

Note

•

If "None" is specified, the call is transferred to the Overflow
Destination immediately.

Reference

• 1.3 System Features (F/G)

– Operator Group