Checking the inlet pressure 

•

  Prior to installing the filter, check the two 

seals (21) on the filter and the seal (16) for 
damage, if necessary renew. 

 

 

•

  Unplug the electric cable from the socket. 

•

  Open the pressure line and drain the water 

off until the pump is completely empty. 

 

The seal (25) must be correctly inserted in 
the seal seat on the pump head (see Detail 
in Fig. C). If necessary lightly grease the 
seal with non-acidic fat.

•

  Check the inlet pressure at the diaphragm 

(5). 

•

  The pressure should be approx. 1.5 bar. 

Correct the pressure if needed. 

•

  Install the filter, screw on filter cover and 

tighten firmly with the hand using filter span-
ner. 

•

  Put the domestic water system into operation 

as set out in the instructions. 

Disposal 

Removing and mounting of non-return 
valve, cleaning  

 

RL 2002/96 EG

Do not dispose of worn-out units 
through the household garbage! 
The appliance, its packaging and 
accessories are all produced 
from recyclable materials and 
must be disposed of accordingly. 

•

  Remove the filter (see Section "cleaning the 

filter"). 

•

  Unscrew the non-return valve (23) and clean 

it under flowing water. 

•

  Renew seal (24) if necessary. 

•

  Install the non-return valve. 

•

  Install the filter and filter cover. 

 
 

Frost protection 

 

Your domestic water system is susceptible to low 
temperatures. Make sure to empty the device of 
residual liquid (hoses, pump and reservoir) and 
store it so that it is protected from frost. 

 
 
 
 

•

  Empty the suction and pressure hoses. 

 

•

  Remove the draining screws (9) and (12) 

drain all water from the pump chamber. The 
water contained in the reservoir will be 
pressed out by the air bellows. 

 
 
 
 

•

  Replace the draining screws and store the 

device so that it is protected from frost. 

 
 
 

Setting the pressure switch 

 
 

The cut-in and cut-out pressures at which the 
sys- tem starts and stops operating have been 
set in the factory (see technical data). However, 
if desired, you can adjust the setting as desired 
at the pressure switch (10).  

 
 
 
 
 

 

Settings on the pushbutton switch and on 
the electrical part of the house water plant 
may be performed only by the responsible 
customer service. 

 