background image

 

 

•

  Make sure that the device is protected from 

rain and any direct exposure to water. 

 

When attaching the suction and pressure 
hoses, make sure that they do not exert a 
tension on the device. We recommend the 
use of flexible hoses at the pump inlet (13) 
and outlet (3). If you have any questions, 
ask your retailer.  

 

When operating the system (

automatic 

operation

), take appropriate measures to 

ensure that damage due to flooding can- 
not occur if the system should malfunction. 
This can be ensured, for instance, by 
installing an alarm system or a reserve 
pump.

 

Attaching the suction hose 

 

Choose a hose which is long enough so 
that the device will not suck in air and run 
dry. The hose should be at least 30cm 
under the surface of the liquid to be 
pumped while the pump is in operation. 

•

  Attach the suction hose. Make sure to screw 

it in tightly, but take care not to damage the 
threads. 

 

If the liquid to be pumped is deeper than 
4 m, you should use a suction hose which 
is larger than 1“ in diameter for the best 
performance. We recommend our AL-KO 
suction set (14), which consists of a 
suction hose, strainer and non-return 
valve. The suction set is available at your 
local retailer’s.  

GB 3 

 

Translation of original user instructions 

•

  When laying the suction hose, make sure 

that it is lower than the system. 

 

If the suction hose is laid so that it is higher 
than the device, bubbles will be- come 
trapped in the line and the pump will suck 
air.  

Attaching the pressure hose 

•

  Screw the connection nipple (17) with the 

round seal ring (18) in the pump outlet (3). 

•

  Screw the angular nipple (15) with the flat 

seal (16) on the connection nipple (17) and 
rotate the angular nipple in the desired direc-
tion. 

•

  Attach the pressure hose. Make sure to 

screw it in tightly, but take care not to dam-
age the threads. 

 

Filling the pump 

 

Before putting your domestic water sys- 
tem into operation, you must fill the pump 
chamber with water until it overflows to 
achieve full suction power. Do not operate 
the pump while it is dry because this will 
cause serious damage to the pump. 

•

  Remove the filler screw (2). 

•

  Pour water into the opening until the cham-

ber of the pump (12) is full. 

•

  Replace the filler screw (2) and tighten it. 

Switching on the system 

•

  Open the pressure line (open valve, sprayer, 

tap, etc.). 

•

  Plug the electric cable into the socket. The 

pump will automatically begin to run. 

•

  As soon as the flow of water is cleared of air 

bubbles trapped in the line, close the pres-
sure line. When the pressure has fallen and 
the reservoir is full, the pump will automati-
cally switch off. Your domestic water system 
is now ready for operation. 

Switching

 off the system 

•

  Switch the system off by unplugging the 

electric cable from the socket. 

Maintenance and Cleaning 

!

 

Before beginning any maintenance or 
cleaning work, make sure that the device 
has been unplugged and take precautions 
to ensure that it cannot be switched on 
during work! 

Cleaning the system 

If you have used your domestic water system to 
pump chlorine water (swimming pool water) or 
liquids which leave a residue, flush your pump 
out with clear water after use. 

Cleaning the filter  

•

  Remove the screw plug (12) from the  drain-

age opening, empty the filter chamber and 
close the drainage opening again 

•

  Unscrew the filter cover (14) with the help of 

the filter spanner. 

•

  Remove the filter (22) from the pump head 

and clean it under flowing water. 