Руководство пользователя для Karcher CB 2 23, CB 2 25, CB 2 28 exclusive :: Страница 37 из 380
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

     

- 

15

19

CAN bus error, module A14, no connec-
tion (water distributor)

Loose connecting chord of the  plates, 
plates defective 

Switch off and switch on the unit, repeat 
washing process, call Customer Service

20

CAN bus error, module A13, no connec-
tion (feed distributor)

21

CAN bus error, module A11, no connec-
tion (in main switching cabinet CB2)

22

CAN bus error, module A12, no connec-
tion (in main switching cabinet CB2)

23

CAN bus error, module A7, no connection 
(water distributor CB2)

24

CAN bus error, module A21, no connec-
tion (anti-frost)

25

CAN bus error, module A22, no connec-
tion (underbody washing)

26

CAN bus error, module A23, no connec-
tion (gate control)

27

CAN bus error, module A24, no connec-
tion (gate control)

28

CAN bus error, module A25, no connec-
tion (washing phase display)

29

CAN bus error, module A26, no connec-
tion (Interface wash card reader in feed 
distributor)

30

CAN bus error, module A27, no connec-
tion (high pressure pump)

31

CAN bus error, module A28, no connec-
tion (external dosing pumps)

32

Excess current outlets CAN Bus module 
A10 (main plate)

Short circuit, water leakage

35

Excess current outlets CAN Bus module 
A14 (water distributor)

36

Excess current outlets CAN Bus module 
A13 (feed distributor)

37

Excess current outlets CAN Bus module 
A11 (in main switching cabinet CB1)

38

Excess current outlets CAN Bus module 
A12 (in main switching cabinet CB1)

40

Excess current outlets CAN Bus module 
A21 (anti-frost)

41

Excess current outlets CAN Bus module 
A22 (underbody cleaning)

42

Excess current outlets CAN Bus module 
A23 (gate control)

43

Excess current outlets CAN Bus module 
A24 (gate control)

44

Excess current outlets CAN Bus module 
A25 (washing phase display)

Short circuit, water leakage

Switch off and switch on the unit, repeat 
washing process, call Customer Service

45

Excess current outlets CAN Bus module 
A26 (Interface wash card reader in feed 
distributor)

46

Excess current outlets CAN Bus module 
A27 (high pressure pumps)

47

Excess current outlets CAN Bus module 
A28 (external dosing pumps)

48

EE_prom not read

Error in  main plate

Switch off and switch on the unit, repeat 
washing process, call Customer Service

49

E_prom checksum error

Display Fault

Possible cause

Remedy

37