– 10

The closer this nozzle is to the contaminated ar-
ea, the higher the cleaning effect, as the temper-
ature and the steam are highest at the nozzle 
output. Especially suited for cleaning difficult ac-
cess locations, joints, fittings, drains, sinks, toi-
lets, blinds and heaters. Heavy lime scale can be 
drenched in vinegar prior to steam-cleaning. Let 
the vinegar penetrate for about 5 minutes.

The round brush can be installed onto the detail 
nozzle as an accessory. Attached brushes can 
therefore be used to remove heavy soiling.

Caution

Not suited for the cleaning of sensitive surfaces.

Illustration 
Attach the round brush to the detail nozzle.

Pull the terry cloth cover over the hand nozzle. 
Especially well-suited for small washable areas, 
shower stalls and mirrors.

Suited for all washable walls and floor coverings, 
e.g. stone floors, tiles and PVC floors. Work 
slowly on very dirty surfaces to allow the steam 
to act on the dirt for a longer period of time.

Note: 

Detergent residue or care emulsions that 

are still present on the surfaces to be cleaned, 
can lead to smears when steam cleaned. How-
ever, these will disappear with repeated cleaning 
procedures.

Illustration 
Attach the floor cloth to the floor nozzle.

1

Fold the floor cloth the long way and place 
the floor nozzle on top of it.

2

Open holding clamps.

3

Place the cloth ends into the openings.

4

Close the holding clamps.

Caution

Do not insert fingers between the clamps.

Illustration 
During work breaks, hook the floor nozzle 
into the parking holder.

Danger

Always disconnect the mains plug and allow the 
steam cleaner to cool down before performing 
any maintenance work.

Rinse the steam cleaner boiler at the latest after 
10 boiler fillings.

Fill the boiler with water and shake it strong-
ly. This dissolves lime scaling residing on the 
boiler bottom. 

Empty water out.

Note: 

If you always use usual commercial distilled 

water it is not necessary to descale the boiler.

As limescale builds up on the boiler walls, we 
recommend to descale the boiler in the following 
intervals (RF=reservoir fillings):

Note:

 Please contact your Conservancy Board 

or the local water supply company to inquire 
about the hardness of your water.

Disconnect the mains plug from the socket.

Allow device to cool down.

Remove the safety cap from the device.

Completely empty the steam boiler to re-
move existing water (see fig.  ).

몇

Warning

Only use products approved by KÄRCHER to 
exclude any damages of the appliance.

User the KÄRCHER decalcifier sticks (order 
no. 6.295-047) to decalcify the water. Please 
follow the dosing instructions on the packag-
ing while using the decalcifying solution.

Caution

Use caution when filling and emptying the steam 
cleaner. The descaling solution can have an ag-
gressive effect on delicate surfaces.

Pour the descaling solution into the boiler 
and allow it to react for approximately 8 
hours.

Detail nozzle

Round brush

Hand nozzle

Floor nozzle

Parking the floor nozzle

Maintenance and care

Rinsing the boiler

Descaling the boiler

Degree of hardness

° dH

mmol/l

RF

I

soft

0- 7 

0-1,3

55

II

medium

7-14

1,3-2,5

45

III hard

14-21 2,5-3,8

35

IV very hard

>21

>3,8

25

17